ARCHITECT AND ENGINEER SPECIFICATIONS

Single Door Introduction
Single Door Features & Diagram
Hub Control Modules and Front-Ends

Architect and Engineer Specifications

General Specification for Access Control Hub Control Module

General Specification for Access Controller Unit

THE CONTROL UNIT shall be of a size which recesses into a standard single-gang electricalfixture. The control unit shall have twelve tactile push-buttons upon its visible face to allow entry of data to the control unit. Each of the twelve tactile push-buttons shall bear one of the following nomenclatures with all nomenclatures being represented by one tactile push-button: 1; 2; 3; 4; 5; 6; 7; 8; 9; 0; *; #. The control unit shall accept properly entered data only when in a valid programming state, which shall be accessed through entry of a preselected master combination of the tactile push-buttons of the control unit. The control unit shall indicate valid entry into and presence in the programming state by flashing an amber light emitting diode. Data entered by means of the tactile push-buttons on the visible face of the control unit shall be stored in memory and used by the control unit during its normal operational state. The control unit shall contain a piezoelectric sounding device which, when in the control units defaulted state, shall indicate the positive actuation of any of the tactile push-buttons by emitting a short burst of sound. The control unit shall have three light emitting diodes. The light emitting diodes shall be of the types: amber, red/green, infrared. The light emitting diodes shall be visible through the face of the control unit and shall be protected with a translucent membrane. In the normal operational state of the control unit, the light emitting diodes shall have the following dispositions: amber-off, red/green-red, infrared-off.

THE CONTROL UNIT shall store up to five hundred unique sets of data for comparison to data input. The control unit shall have two way communication with up to two data input devices and shall communicate in a proprietary serial format. The control unit shall contain form C relays preassigned to the following functions: Lock Release, Alarm Zone Shunt, Forced Door, Propped Door. The control unit shall contain two input loops assigned to the following functions: Request to Exit, Door Position Sensor. The control unit shall store in memory, records of operations (transactions) up to the quantity of 500. These records shall contain the following data: user number, door number, time, date. The control unit shall contain a real-time clock for facilitation of the transactions. The control unit shall be capable of transfering the transactions to both a serial printer and an infrared printer. The serial printer shall connect directly ot the control unit. The infrared output of the transactions shall be througth the face of the control unit.

BACK TO TOP

General Specification for Secured Series Keypads

a. Secured Series Weatherproof Keypad
b. Secured Series Mullion Keypad
c. Secured Series Weather Resistant Keypad
d. Secured Series Indoor Keypad
e. Secured Series Weatherproof Ruggedized Keypad
f. Secured Series Weatherproof Magnetic Card Reader Keypad

General Specification for Access Controller Unit

THE CONTROL UNIT shall be of a size which recesses into a standard single-gang electrical fixture. The control unit shall have twelve tactile push-buttons upon its visible face to allow entry of data to the control unit. Each of the twelve tactile push-buttons shall bear one of the following nomenclatures with all nomenclatures being represented by one tactile push-button: 1; 2; 3; 4; 5; 6; 7; 8; 9; 0; *; #. The control unit shall accept properly entered data only when in a valid programming state, which shall be accessed through entry of a preselected master combination of the tactile push-buttons of the control unit. The control unit shall indicate valid entry into and presence in the programming state by flashing an amber light emitting diode. Data entered by means of the tactile push-buttons on the visible face of the control unit shall be stored in memory and used by the control unit during its normal operational state. The control unit shall contain a piezoelectric sounding device which, when in the control units defaulted state, shall indicate the positive actuation of any of the tactile push-buttons by emitting a short burst of sound. The control unit shall have three light emitting diodes. The light emitting diodes shall be of the types: amber, red/green, infrared. The light emitting diodes shall be visible through the face of the control unit and shall be protected with a translucent membrane. In the normal operational state of the control unit, the light emitting diodes shall have the following dispositions: amber-off, red/green-red, infrared-off.

THE CONTROL UNIT shall store up to five hundred unique sets of data for comparison to data input. The control unit shall have two way communication with up to two data input devices and shall communicate in a proprietary serial format. The control unit shall contain form C relays preassigned to the following functions: Lock Release, Alarm Zone Shunt, Forced Door, Propped Door. The control unit shall contain two input loops assigned to the following functions: Request to Exit, Door Position Sensor. The control unit shall store in memory, records of operations (transactions) up to the quantity of 500. These records shall contain the following data: user number, door number, time, date. The control unit shall contain a real-time clock for facilitation of the transactions. The control unit shall be capable of transfering the transactions to both a serial printer and an infrared printer. The serial printer shall connect directly ot the control unit. The infrared output of the transactions shall be througth the face of the control unit.

BACK TO TOP

General Specification for Secured Series Card/Token Readers

a. Secured Series Weatherproof Magnetic Card Reader
b. Secured Series Weatherproof Single-gang Proximity Reader
c. Secured Series Weatherproof Mullion Proximity Reader
d. Secured Series Weatherproof Touch Memory Reader
e. Secured Series Weatherproof Magnetic Card Reader Keypad

General Specification for Access Controller Readers

1. The following Reader types and styles shall be available and used interchangeably with the Control Unit:

A. A SINGLE PIECE weatherproof magnetic card reader capable of mounting on a standard aluminum or wood door frame. The reader will connect to the control unit with four wires and will communicate with the control unit over two of the four wires using a proprietary serial communication method. The reader shall contain two light emitting diodes (LED) which will be controlled by the control unit. The light emitting diodes shall be of the types: amber, red/green. The light emitting diodes shall be visible through the face of the reader and shall be protected with a translucent membrane. In the normal operational state of the control unit, the light emitting diodes shall have the following dispositions: amber-off, red/green-red. The reader shall contain a piezoelectric sounding device which, when in the control units defaulted state, shall indicate the positive presentation of an access control proximity card or token by emitting a short burst of sound. The dimensions of the reader shall be 4.5" high x 1.75" wide x 1.55" deep. The material of the housing shall be machined aluminum.

B. A TWO PIECE weatherproof proximity wall switch reader capable of being mounted directly on a standard metal or plastic single-gang electrical box or on a flat wall with the secondary electronics being remote. The secondary electronics will connect to the control unit with four wires and will communicate with the control unit over two of the four wires using a proprietary serial communication method. The reader shall contain a light emitting diode (LED) which will be controlled by the control unit. The light emitting diode shall be of the type: red/green. The light emitting diode shall be visible through the face of the reader. In the normal operational state of the control unit, the light emitting diode shall have the following disposition: red. The reader shall contain a piezoelectric sounding device which, when in the control units defaulted state, shall indicate the positive presentation of an access control proximity card or token by emitting a short burst of sound. The dimensions of the reader without electronics shall be 4.6" high x 5.5" wide x 0.5" deep.

C. A TWO PIECE weatherproof proximity reader capable of being mounted on a flat wall or door/window frame with the secondary electronics being remote. The secondary electronics will connect to the control unit with four wires and will communicate with the control unit over two of the four wires using a proprietary serial communication method. The reader shall contain a light emitting diode (LED) which will be controlled by the control unit. The light emitting diode shall be of the type: red/green. The light emitting diode shall be visible through the face of the reader. In the normal operational state of the control unit, the light emitting diode shall have the following disposition: red. The dimensions of the reader without electronics shall be 5.5" high x 1.6" wide x 0.75" deep.

D. A SINGLE PIECE weatherproof Touch Memory Reader capable of being mounted directly on a standard metal or plastic single-gang electrical box. The reader shall utilize the Dallas Semiconductor Touch Memory technology. The reader will connect to the control unit with four wires and will communicate with the control unit over two of the four wires using a proprietary serial communication method. The reader shall contain a light emitting diode (LED) which will be controlled by the control unit. The light emitting diode shall be of the types: red/green. The light emitting diode shall be visible through the face of the control unit and shall be protected behind the translucent contact point. In the normal operational state of the control unit, the light emitting diode shall have the following disposition: red. The reader shall contain a piezoelectric sounding device which, when in the control units defaulted state, shall indicate the positive presentation of an access control token by emitting a short burst of sound. The dimensions of the reader shall be 4.5" high x 2.75" wide x 0.5" deep. The material of the housing shall be machined aluminum.

E. A SINGLE PIECE weatherproof Magnetic Card Reader/Keypad capable of being mounted directly on a standard metal or plastic single-gang electrical box. The reader/keypad will connect to the control unit with four wires and will communicate with the control unit over two of the four wires using a proprietary serial communication method. The reader/keypad shall contain two light emitting diodes (LED) which will be controlled by the control unit. The light emitting diodes shall be of the types: amber, red/green. The light emitting diodes shall be visible through the face of the reader/keypad and shall be protected with a translucent membrane. In the normal operational state of the control unit, the light emitting diodes shall have the following dispositions: amber-off, red/green-red. The reader shall contain a piezoelectric sounding device which, when in the control units defaulted state, shall indicate the positive actuation of any of the tactile push-buttons by emitting a short burst of sound. The dimensions of the reader/keypad shall be 4.5" high x 4.5" wide x 1.55" deep. The material of the housing shall be machined aluminum.

BACK TO TOP

2. THE BI-COLOR light emitting diode (LED) shall indicate to the user that access has been grated by switching from read to green for a time period designated by the control unit.

3. MAGNETIC CARD READERS shall be capable of demonstrating the presence of valid track two data on magnetic stripe cards by a rapid flashing of the green (bi-color) LED.

4. ELECTRICAL CONNECTIONS to the control unit shall be via multi-conductor, #24 AWG, #22 AWG or #18 AWG shielded cable. No special connectors shall be necessary.

5. ELECTRICAL CONNECTIONS from the reader to the control unit shall be capable of distances of up to 1000' without requiring any further components or signal boosting equipment.

6. THE READER SHALL contain no relays or other switching mechanisms which could be compromised by vandalism.

To enquire about this product series, please complete our enquiry form

Link to IEI

To visit International
Electronics Inc.
home on the Web,
click here.

BACK TO TOP
SINGLE DOOR INTRODUCTION | SINGLE DOOR FEATURES & DIAGRAM | HUB CONTRL MODULES AND FRONT-ENDS
Entry Systems

Contact Us | Company Profile | Video Transmission Systems | Enquiry Form

Click here to email


This site was designed and produced by
Internet PageMakers