Features
- Two-Way Transmission Over One or
Two Multimode Fibres.
- Used With Aiphone, Bogen,
Dukane, Rauland, or Stentofon Systems.
- AGC Circuitry.
- Diagnostic Indicators:
Level/LossTM and
Audio.
- Modular Units or Rack
Cards.
- Operates Over Distances Up To
10,000 Feet (3048 Meters).
Architect
and Engineer Specifications
Audio
- Audio
Bandwidth: 200 Hz to 5 kHz.
- Signal-to-Noise
Ratio: > 50 dB @ maximum optical
attenuation.
- I/O Levels for
Master and Remote units: Per manufacturer's
specifications.
- I/O Impedance:
Per manufacturer's specifications.
- Connectors:
Optical, AT&T Type ST; 10-pin screw
terminal.
|