Product Line

Fiber Options

Audio Systems

341A-Touchtone Telephone Interface
Multimode Fibre | Single-Mode Fibre

Features

Specifications

Diagram

Back to Audio Systems Index


Features

  • Two-Way Transmission Over One or Two Multimode Fibres.
  • Meets FCC Regulations-Part 68 (FCC Version).
  • AGC Circuitry.
  • Diagnostic Indicators: Level/LossTM LED at the Receiving End.
  • True 90 V RMS AC ring Voltage.
  • Modular or Rack-Mount Units.
  • Operates Over Distances Up To 10,000 Feet (3048 Meters).

Architect and Engineer Specifications

Audio

  • Audio Bandwidth: 150 Hz to 5 kHz.
  • Signal-to-Noise Ratio: > 50 dB @ maximum optical attenuation.
  • I/O Impedance: 600 ohms balanced.
  • I/O Standard Touchtone Telephone
  • Connectors: Optical, AT&T Type ST; Audio (Phone Line) Connector, RJ11C.

Power/Temperature/Size

  • 12 VAC @ 1 amp; + 14~16 VDC.
  • Operates at 32° to 122° F (0° to 50° C).
  • Storage at -40° to 185° F (-40° to 85° C).
  • Two-Fibre Modular units: 4.5" W x 4.0" D x 1.8" H (11.56 x 10.2 x 4.95 cm).
  • One-Fibre Rack units: Occupy two rack slots. Two-Fibre Rack units: Occupy one rack slot.

341A Diagram

Single-mode fibre version of this product is available. The model number is 2210D.